← tous les HP

18 Sound 8NMB750

8" · 8 Ω · 350 W · 96.5 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale8"
Impédance8 Ω
Fs88 Hz
Qts0.27
Qes0.28
Qms6.1
Vas6.9 L
Sd230 cm²
Xmax6.1 mm
Re5.2 Ω
Bl18.7 T·m
Mms35 g
Pe350 W
Sensibilité96.5 dB

Indication d'alignement

EBP314 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 1.2 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
LaVoce WAN082.0185 -30.32 +0.059 +2.15.8 -0.396 -0.5usable200 W vs 350 W: lower power handling · Xmax 5.8 mm < 6.1 mm: lower excursion-limited SPL+
LaVoce WAN082.0280 -80.23 -0.048.97 +2.075.8 -0.396.5 =usable200 W vs 350 W: lower power handling · Xmax 5.8 mm < 6.1 mm: lower excursion-limited SPL+
18 Sound 8NMB75091 +30.37 +0.17.3 +0.46.3 +0.295 -1.5usable16 Ω vs 8 Ω: amp load changes+
B&C 8NW5176 -120.25 -0.0210.6 +3.76 -0.197 +0.5usable4 Ω vs 8 Ω: amp load changes · 200 W vs 350 W: lower power handling · Xmax 6 mm < 6.1 mm: lower excursion-limited SPL+
B&C 8NDL6480 -80.25 -0.029.6 +2.74.5 -1.697 +0.5usableXmax 4.5 mm < 6.1 mm: lower excursion-limited SPL+
Oberton 8NMB250v482.03 -5.970.258 -0.0110.89 +3.994.5 -1.696 -0.5usable250 W vs 350 W: lower power handling · Xmax 4.5 mm < 6.1 mm: lower excursion-limited SPL+
BMS 8N51587.7 -0.30.3 +0.0311.04 +4.144 -2.196 -0.5usable200 W vs 350 W: lower power handling · Xmax 4 mm < 6.1 mm: lower excursion-limited SPL+
BMS 8S21587.7 -0.30.31 +0.0411.04 +4.144.25 -1.8596 -0.5usable200 W vs 350 W: lower power handling · Xmax 4.25 mm < 6.1 mm: lower excursion-limited SPL+
18 Sound 8NTLW200074 -140.26 -0.0111.3 +4.44.4 -1.796.5 =usable16 Ω vs 8 Ω: amp load changes · Xmax 4.4 mm < 6.1 mm: lower excursion-limited SPL+
LaVoce WAF082.0176 -120.21 -0.0610.21 +3.315.8 -0.397 +0.5usable250 W vs 350 W: lower power handling · Xmax 5.8 mm < 6.1 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 8NMB750 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.