← tous les HP

18 Sound 18iD

18" · 2 Ω · 1800 W · 95 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale18"
Impédance2 Ω
Fs40 Hz
Qts0.26
Qes0.27
Qms5.5
Vas67 L
Sd1225 cm²
Xmax15.5 mm
Re1.5 Ω
Bl24 T·m
Mms420 g
Pe1800 W
Sensibilité95 dB

Indication d'alignement

EBP148 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 10.5 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
18 Sound 18NLW960138 -20.28 +0.02111 +4414 -1.596 +1usable4 Ω vs 2 Ω: amp load changes · Xmax 14 mm < 15.5 mm: lower excursion-limited SPL+
18 Sound 18NLW960139 -10.28 +0.02120 +5314 -1.596 +1usable8 Ω vs 2 Ω: amp load changes · Xmax 14 mm < 15.5 mm: lower excursion-limited SPL+
18 Sound 18NLW9601C38 -20.34 +0.0899 +3214 -1.595 =usable8 Ω vs 2 Ω: amp load changes · Xmax 14 mm < 15.5 mm: lower excursion-limited SPL+
18 Sound 18NTLS500037 -30.33 +0.0775 +817.75 +2.2589 -6usable4 Ω vs 2 Ω: amp load changes+
18 Sound 18NLW450037 -30.31 +0.05127 +6014.75 -0.7596.5 +1.5usable4 Ω vs 2 Ω: amp load changes · Xmax 14.75 mm < 15.5 mm: lower excursion-limited SPL+
B&C 18RS11533 -70.22 -0.04125 +5823.5 +897.4 +2.4usable8 Ω vs 2 Ω: amp load changes+
B&C 18SW11534 -60.3 +0.04149.1 +82.114 -1.596 +1usable4 Ω vs 2 Ω: amp load changes · Xmax 14 mm < 15.5 mm: lower excursion-limited SPL+
PD PD 185NR134 -60.277 +0.02102 +356.3 -9.295.1 +0.1risky8 Ω vs 2 Ω: amp load changes · 1400 W vs 1800 W: lower power handling · Xmax 6.3 mm < 15.5 mm: lower excursion-limited SPL+
Precision Devices PD 185NR134 -60.277 +0.02102 +356.3 -9.295.1 +0.1risky8 Ω vs 2 Ω: amp load changes · 1400 W vs 1800 W: lower power handling · Xmax 6.3 mm < 15.5 mm: lower excursion-limited SPL+
B&C 18DS10034 -60.29 +0.03155 +8814.5 -197.5 +2.5risky8 Ω vs 2 Ω: amp load changes · Xmax 14.5 mm < 15.5 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 18iD →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.