18 Sound 15W700
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 41 Hz |
| Qts | 0.27 |
| Qes | 0.29 |
| Qms | 4.03 |
| Vas | 180 L |
| Sd | 850 cm² |
| Xmax | 6.5 mm |
| Re | 2.8 Ω |
| Bl | 14.7 T·m |
| Mms | 86 g |
| Pe | 450 W |
| Sensibilité | 97 dB |
Indication d'alignement
| EBP | 141 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 30.7 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| SICA 15 K3 PL-8 | 40 -1 | 0.27 = | 166.1 -13.9 | 6.5 = | 97.6 +0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 15NLW9300 | 39 -2 | 0.26 -0.01 | 170 -10 | 8 +1.5 | 97 = | close | 8 Ω vs 4 Ω: amp load changes | + |
| BMS 15N830V2 | 39.5 -1.5 | 0.27 = | 159 -21 | 8 +1.5 | 97.1 +0.1 | close | 6 Ω vs 4 Ω: amp load changes | + |
| Sica 15 K 3 PL | 40 -1 | 0.27 = | 166.1 -13.9 | 6.5 = | 99.7 +2.7 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 15NLW9300 v2015 | 39 -2 | 0.263 -0.01 | 170 -10 | 7.2 +0.7 | 98.9 +1.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane COLOSSUS 15XBN | 38 -3 | 0.279 +0.01 | 168 -12 | 7.5 +1 | 98.1 +1.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Precision Devices PD.153C01 | 39 -2 | 0.27 = | 195 +15 | 5.7 -0.8 | 98.1 +1.1 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.7 mm < 6.5 mm: lower excursion-limited SPL | + |
| Beyma 15G400 | 35 -6 | 0.271 = | 175 -5 | 6.1 -0.4 | 97.5 +0.5 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6.1 mm < 6.5 mm: lower excursion-limited SPL | + |
| JBL 2226J | 40 -1 | 0.31 +0.04 | 175.6 -4.4 | 7 +0.5 | 96.3 -0.7 | close | 16 Ω vs 4 Ω: amp load changes | + |
| Precision Devices PD152 | 40 -1 | 0.269 = | 170 -10 | 5.5 -1 | 99 +2 | close | 16 Ω vs 4 Ω: amp load changes · Xmax 5.5 mm < 6.5 mm: lower excursion-limited SPL | + |