18 Sound 12W500
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 49 Hz |
| Qts | 0.35 |
| Qes | 0.37 |
| Qms | 6.1 |
| Vas | 101 L |
| Sd | 531 cm² |
| Xmax | 4 mm |
| Re | 2.7 Ω |
| Bl | 9.6 T·m |
| Mms | 36.5 g |
| Pe | 350 W |
| Sensibilité | 98.5 dB |
Indication d'alignement
| EBP | 132 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 32.8 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fane SOVEREIGN 12-300 v2014 | 46 -3 | 0.35 = | 110 +9 | 4.5 +0.5 | 98 -0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Faital PRO 12PR300 | 50 +1 | 0.36 +0.01 | 92.6 -8.4 | 4.92 +0.92 | 99 +0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane SOVEREIGN 12-300 | 50 +1 | 0.389 +0.04 | 103.6 +2.6 | 4.5 +0.5 | 98.4 -0.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane SOVEREIGN PRO 12-300 | 46 -3 | 0.35 = | 114 +13 | 4.5 +0.5 | 98.1 -0.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| RCF MB 12N251 | 50 +1 | 0.338 -0.01 | 83 -18 | 5 +1 | 98.5 = | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane SOVEREIGN PRO 12-350N | 46 -3 | 0.328 -0.02 | 114 +13 | 4.5 +0.5 | 98.4 -0.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Benett 12.180 X/N | 49 = | 0.325 -0.02 | 100.9 -0.1 | 3 -1 | 98.5 = | close | 8 Ω vs 4 Ω: amp load changes · 100 W vs 350 W: lower power handling · Xmax 3 mm < 4 mm: lower excursion-limited SPL | + |
| Eminence DELTA PRO 12A | 51 +2 | 0.35 = | 81.7 -19.3 | 4.6 +0.6 | 99.2 +0.7 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Faital PRO 12PR300 v2015 | 50 +1 | 0.357 +0.01 | 79.2 -21.8 | 4.9 +0.9 | 98 -0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 12W501 | 46 -3 | 0.369 +0.02 | 123 +22 | 4 = | 98.7 +0.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 12W500 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.