18 Sound 12NLW9300 v2022
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 47 Hz |
| Qts | 0.416 |
| Qes | 0.45 |
| Qms | 5.5 |
| Vas | 56 L |
| Sd | 531 cm² |
| Xmax | 8 mm |
| Re | 4.7 Ω |
| Bl | 15.8 T·m |
| Mms | 80.9 g |
| Pe | 800 W |
| Sensibilité | 95.4 dB |
Indication d'alignement
| EBP | 104 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 29.6 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| 18 Sound 12NLW9300 | 47 = | 0.42 = | 56 = | 8 = | 97 +1.6 | close | + | |
| Beyma 112Nd/W | 48 +1 | 0.415 = | 55 -1 | 7.4 -0.6 | 95 -0.4 | close | Xmax 7.4 mm < 8 mm: lower excursion-limited SPL | + |
| B&C 12NDL88 | 50 +3 | 0.37 -0.05 | 55 -1 | 8 = | 97 +1.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
| P.Audio SN-12LF | 48 +1 | 0.399 -0.02 | 67.9 +11.9 | 7.2 -0.8 | 96 +0.6 | close | 600 W vs 800 W: lower power handling · Xmax 7.2 mm < 8 mm: lower excursion-limited SPL | + |
| Faital PRO 12HP1010 | 45 -2 | 0.34 -0.08 | 56.5 +0.5 | 9.25 +1.25 | 96 +0.6 | close | + | |
| Oberton 12B45V | 47.88 +0.88 | 0.354 -0.06 | 58.51 +2.51 | 10.5 +2.5 | 94 -1.4 | close | 450 W vs 800 W: lower power handling | + |
| Eminence OMEGA PRO-12-2KW-8 | 48.14 +1.14 | 0.39 -0.03 | 49.55 -6.45 | 7.1 -0.9 | 93.33 -2.07 | close | Xmax 7.1 mm < 8 mm: lower excursion-limited SPL | + |
| 18 Sound 12NTLS3500 | 41 -6 | 0.41 -0.01 | 65 +9 | 7.9 -0.1 | 93.5 -1.9 | close | Xmax 7.9 mm < 8 mm: lower excursion-limited SPL | + |
| Beyma 12"LX60V2 | 49 +2 | 0.38 -0.04 | 43 -13 | 9 +1 | 96 +0.6 | close | + | |
| B&C 12 NDL 88 16 Ohms | 50 +3 | 0.363 -0.05 | 55 -1 | 7.1 -0.9 | 93.1 -2.3 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 7.1 mm < 8 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 12NLW9300 v2022 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.