18 Sound 12ND610
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 46 Hz |
| Qts | 0.14 |
| Qes | 0.15 |
| Qms | 4.3 |
| Vas | 94.4 L |
| Sd | 531 cm² |
| Xmax | 3.5 mm |
| Re | 5.9 Ω |
| Bl | 24 T·m |
| Mms | 49 g |
| Pe | 450 W |
| Sensibilité | 102 dB |
Indication d'alignement
| EBP | 307 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 3.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma 12P80Nd | 45 -1 | 0.147 +0.01 | 95.7 +1.3 | 5.5 +2 | 101.5 -0.5 | close | + | |
| RCF L 12P110K | 44 -2 | 0.136 = | 98 +3.6 | 3 -0.5 | 101.3 -0.7 | close | Xmax 3 mm < 3.5 mm: lower excursion-limited SPL | + |
| RCF L12P110K | 44 -2 | 0.13 -0.01 | 98 +3.6 | 3 -0.5 | 99.6 -2.4 | close | 250 W vs 450 W: lower power handling · Xmax 3 mm < 3.5 mm: lower excursion-limited SPL | + |
| Monacor SP-30PAX | 46 = | 0.164 +0.02 | 130 +35.6 | 3.9 +0.4 | 102.3 +0.3 | usable | 200 W vs 450 W: lower power handling | + |
| 18 Sound 12MB600 | 46 = | 0.19 +0.05 | 86 -8.4 | 4.5 +1 | 101 -1 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 12MB700 | 49 +3 | 0.19 +0.05 | 101 +6.6 | 4.5 +1 | 101.5 -0.5 | usable | + | |
| 18 Sound 12MB777 | 49 +3 | 0.19 +0.05 | 101 +6.6 | 4.5 +1 | 101.5 -0.5 | usable | + | |
| RCF L 12/584 | 49 +3 | 0.186 +0.05 | 100 +5.6 | 3 -0.5 | 101.6 -0.4 | usable | 200 W vs 450 W: lower power handling · Xmax 3 mm < 3.5 mm: lower excursion-limited SPL | + |
| JBL 2202H | 50 +4 | 0.171 +0.03 | 87.8 -6.6 | 2.6 -0.9 | 101.5 -0.5 | usable | 150 W vs 450 W: lower power handling · Xmax 2.6 mm < 3.5 mm: lower excursion-limited SPL | + |
| 18 Sound 12MB600 | 44 -2 | 0.18 +0.04 | 115 +20.6 | 4.5 +1 | 101 -1 | usable | + |
Comparer les 3 plus proches avec le 12ND610 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.