18 Sound 12CX800
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 53 Hz |
| Qts | 0.253 |
| Qes | 0.27 |
| Qms | 4 |
| Vas | 73 L |
| Sd | 530 cm² |
| Xmax | 4.7 mm |
| Re | 5.8 Ω |
| Bl | 18.7 T·m |
| Mms | 48.6 g |
| Pe | 400 W |
| Sensibilité | 99.4 dB |
Indication d'alignement
| EBP | 196 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 10.7 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| RCF MB 12G301 | 53 = | 0.264 +0.01 | 72 -1 | 4.8 +0.1 | 99.5 +0.1 | close | + | |
| RCF MB 12N301 | 54 +1 | 0.24 -0.01 | 71 -2 | 4.9 +0.2 | 99.7 +0.3 | close | + | |
| Oberton 12B400 | 50.47 -2.53 | 0.249 = | 74.74 +1.74 | 5.25 +0.55 | 98 -1.4 | close | + | |
| B&C 12PLB76 | 50 -3 | 0.23 -0.02 | 75 +2 | 5 +0.3 | 99 -0.4 | close | + | |
| 18 Sound 12ND830 | 55 +2 | 0.28 +0.03 | 72 -1 | 6.5 +1.8 | 99 -0.4 | close | + | |
| Monacor SP-12/300NEO | 53 = | 0.252 = | 68 -5 | 3.5 -1.2 | 99.5 +0.1 | close | 300 W vs 400 W: lower power handling · Xmax 3.5 mm < 4.7 mm: lower excursion-limited SPL | + |
| Monacor SP-12A/300NEO | 53 = | 0.252 = | 68 -5 | 3.5 -1.2 | 99.5 +0.1 | close | 300 W vs 400 W: lower power handling · Xmax 3.5 mm < 4.7 mm: lower excursion-limited SPL | + |
| B&C 12 PLB 76 | 50 -3 | 0.229 -0.02 | 75 +2 | 4.4 -0.3 | 99.7 +0.3 | close | Xmax 4.4 mm < 4.7 mm: lower excursion-limited SPL | + |
| Electro-Voice EVM-DL12X | 56 +3 | 0.24 -0.01 | 77.3 +4.3 | 4.1 -0.6 | 99.2 -0.2 | close | 150 W vs 400 W: lower power handling · Xmax 4.1 mm < 4.7 mm: lower excursion-limited SPL | + |
| B&C 12NDL76 | 50 -3 | 0.27 +0.02 | 69 -4 | 7 +2.3 | 100 +0.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 12CX800 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.