18 Sound 10NMB520
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 16 Ω |
| Fs | 64 Hz |
| Qts | 0.33 |
| Qes | 0.36 |
| Qms | 4 |
| Vas | 43 L |
| Sd | 340 cm² |
| Xmax | 4 mm |
| Re | 11.7 Ω |
| Bl | 17.5 T·m |
| Mms | 23 g |
| Pe | 300 W |
| Sensibilité | 100 dB |
Indication d'alignement
| EBP | 178 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 12 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| PHL Audio 3020 | 60 -4 | 0.337 +0.01 | 41 -2 | 4.1 +0.1 | 97.6 -2.4 | close | 8 Ω vs 16 Ω: amp load changes · 200 W vs 300 W: lower power handling | + |
| Fane SOVEREIGN 10-275 | 60 -4 | 0.343 +0.01 | 42.4 -0.6 | 5 +1 | 97.5 -2.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Fane SOVEREIGN 10-300 | 58 -6 | 0.313 -0.02 | 43 = | 4.8 +0.8 | 97.5 -2.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| RCF MB 10N251 (prodance) | 58.9 -5.1 | 0.33 = | 38.8 -4.2 | 4.8 +0.8 | 97.3 -2.7 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Fane SOVEREIGN PRO 10-300 | 58 -6 | 0.322 -0.01 | 41 -2 | 4.7 +0.7 | 97.2 -2.8 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Eminence DELTA 10B | 65 +1 | 0.33 = | 36 -7 | 3.5 -0.5 | 98 -2 | close | Xmax 3.5 mm < 4 mm: lower excursion-limited SPL | + |
| SICA 10 L 2.5 SL 4 Ohms | 56.5 -7.5 | 0.295 -0.04 | 46.9 +3.9 | 4 = | 99.8 -0.2 | close | 4 Ω vs 16 Ω: amp load changes | + |
| 18 Sound 10NMB420 | 65 +1 | 0.33 = | 30 -13 | 4 = | 99 -1 | close | + | |
| Beyma 10XC25 | 63 -1 | 0.376 +0.05 | 41 -2 | 4.5 +0.5 | 97.2 -2.8 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Jensen JB 10/150 | 60 -4 | 0.295 -0.04 | 42 -1 | 3.7 -0.3 | 97.8 -2.2 | close | 8 Ω vs 16 Ω: amp load changes · 150 W vs 300 W: lower power handling · Xmax 3.7 mm < 4 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 10NMB520 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.