Warehouse Sound VETERAN 30
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 8 Ω |
| Fs | 94.8 Hz |
| Qts | 0.733 |
| Qes | 0.78 |
| Qms | 12.15 |
| Vas | 524.7 L |
| Sd | 366.1 cm² |
| Xmax | 2 mm |
| Re | 7.99 Ω |
| Bl | 2.5 T·m |
| Mms | 1 g |
| Pe | 30 W |
| Sensitivity | 109.6 dB |
Alignment hint
| EBP | 122 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Warehouse Sound RETRO 10 | 115.6 +20.8 | 0.601 -0.13 | 460.4 -64.3 | 3 +1 | 113.4 +3.8 | usable | + | |
| Audax HIF24HS vp | 67.6 -27.2 | 0.501 -0.23 | 85.3 -439.4 | 2.5 +0.5 | 102.9 -6.7 | risky | 4 Ω vs 8 Ω: amp load changes | + |
| Visaton W250 v2016 | 45 -49.8 | 0.75 +0.02 | 135 -389.7 | 5 +3 | 94.1 -15.5 | risky | + | |
| Audax HIF24F-2CA12 | 35 -59.8 | 0.694 -0.04 | 191.8 -332.9 | 3.5 +1.5 | 92.3 -17.3 | risky | + | |
| Visaton W250 v2017 | 45 -49.8 | 0.781 +0.05 | 135 -389.7 | 5 +3 | 94.1 -15.5 | risky | + | |
| Beyma 10AG | 50 -44.8 | 0.797 +0.06 | 119 -405.7 | 1.5 -0.5 | 94.1 -15.5 | risky | Xmax 1.5 mm < 2 mm: lower excursion-limited SPL | + |
| Focal 690 CVX | 60.3 -34.5 | 0.693 -0.04 | 59.5 -465.2 | 2.5 +0.5 | 97.8 -11.8 | risky | 4 Ω vs 8 Ω: amp load changes | + |
| LII Audio CRYSTAL-10 | 31.5 -63.3 | 0.479 -0.25 | 256.5 -268.2 | 3 +1 | 95.4 -14.2 | risky | 20 W vs 30 W: lower power handling | + |
| Audax HIF24J37C-2CA12 | 40 -54.8 | 0.449 -0.28 | 208.3 -316.4 | 4 +2 | 96.4 -13.2 | risky | + | |
| Visaton W250 vp Tony | 45 -49.8 | 0.781 +0.05 | 135 -389.7 | 6.4 +4.4 | 91.5 -18.1 | risky | 16 Ω vs 8 Ω: amp load changes | + |
Compare the closest 3 against the VETERAN 30 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.