Visaton W250 vp
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 8 Ω |
| Fs | 55.6 Hz |
| Qts | 1.045 |
| Qes | 1.231 |
| Qms | 6.895 |
| Vas | 58.1 L |
| Sd | 359.7 cm² |
| Xmax | 3.4 mm |
| Re | 6.66 Ω |
| Bl | 7 T·m |
| Mms | 25.6 g |
| Pe | 90 W |
| Sensitivity | 91.9 dB |
Alignment hint
| EBP | 45 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50: favours a sealed (closed) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Beyma HP10 | 61 +5.4 | 1.057 +0.01 | 51 -7.1 | 3.1 -0.3 | 92.1 +0.2 | close | Xmax 3.1 mm < 3.4 mm: lower excursion-limited SPL | + |
| Skytronic SP 1000 | 52 -3.6 | 1.064 +0.02 | 51.6 -6.5 | 6 +2.6 | 90.6 -1.3 | close | + | |
| Goldwood GW-210/4 | 41.8 -13.8 | 1.067 +0.02 | 64.2 +6.1 | 3.5 +0.1 | 90.7 -1.2 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Fenton PS10 vp2 | 59.9 +4.3 | 1.01 -0.03 | 41.2 -16.9 | 3.2 -0.2 | 90.4 -1.5 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 3.2 mm < 3.4 mm: lower excursion-limited SPL | + |
| Eltax MILLENIUM 500 GRAVE vp | 54.6 -1 | 0.95 -0.09 | 38 -20.1 | 4.4 +1 | 88.7 -3.2 | usable | + | |
| Fonestar FPW 250 | 55 -0.6 | 0.825 -0.22 | 38 -20.1 | 3.9 +0.5 | 90.6 -1.3 | usable | + | |
| Monacor SP-250PA v2017 | 48 -7.6 | 0.779 -0.27 | 72 +13.9 | 4.3 +0.9 | 91.7 -0.2 | usable | + | |
| Faital PRO 10FE200 v2014 | 55 -0.6 | 0.695 -0.35 | 53.4 -4.7 | 4.7 +1.3 | 94.1 +2.2 | usable | + | |
| Focal 10C 5401 | 56.5 +0.9 | 0.796 -0.25 | 43.1 -15 | 3.2 -0.2 | 94.6 +2.7 | usable | 4 Ω vs 8 Ω: amp load changes · 60 W vs 90 W: lower power handling · Xmax 3.2 mm < 3.4 mm: lower excursion-limited SPL | + |
| Hyper Phase BF10R | 45 -10.6 | 0.831 -0.21 | 78 +19.9 | 3.5 +0.1 | 90.8 -1.1 | usable | 60 W vs 90 W: lower power handling | + |
Compare the closest 3 against the W250 vp →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.