← all drivers

Sica 6 N 2.5 PL

6" · 8 Ω · 300 W · 92.5 dB · datasheet ↗

Thiele-Small parameters

Nominal size6"
Impedance8 Ω
Fs80 Hz
Qts0.27
Qes0.29
Qms3.05
Vas4.9 L
Sd122.7 cm²
Xmax4.5 mm
Re6.2 Ω
Bl13.5 T·m
Mms17.1 g
Pe300 W
Sensitivity92.5 dB

Alignment hint

EBP276 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 0.8 L

EBP > 100: favours a ported (bass-reflex) alignment.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Substitute candidates

DriverFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)FitNotesCompare
Faital PRO 6FE400100 +200.36 +0.094.9 =4.87 +0.3793 +0.5usable4 Ω vs 8 Ω: amp load changes · 200 W vs 300 W: lower power handling+
LaVoce WSN061.52-490 +100.37 +0.15.15 +0.254 -0.592.5 =usable4 Ω vs 8 Ω: amp load changes · 125 W vs 300 W: lower power handling · Xmax 4 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6PR16090 +100.33 +0.065.9 +15 +0.595 +2.5usable120 W vs 300 W: lower power handling+
Faital PRO 6FE400100 +200.36 +0.095 +0.14.77 +0.2794 +1.5usable200 W vs 300 W: lower power handling+
LaVoce MAN062.00103 +230.3 +0.034.07 -0.833.9 -0.695 +2.5usableXmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6RS14065 -150.27 =9.3 +4.45.6 +1.193 +0.5usable200 W vs 300 W: lower power handling+
LaVoce WSF061.5291 +110.34 +0.076.62 +1.723.8 -0.795 +2.5usable125 W vs 300 W: lower power handling · Xmax 3.8 mm < 4.5 mm: lower excursion-limited SPL+
LaVoce WSN061.5290 +100.39 +0.125.92 +1.023.8 -0.794 +1.5usable125 W vs 300 W: lower power handling · Xmax 3.8 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6FE30098 +180.41 +0.144.4 -0.53.9 -0.692 -0.5usable4 Ω vs 8 Ω: amp load changes · 175 W vs 300 W: lower power handling · Xmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+
LaVoce MAN062.00-16103 +230.34 +0.073.77 -1.133.9 -0.694.5 +2usable16 Ω vs 8 Ω: amp load changes · Xmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+

Compare the closest 3 against the 6 N 2.5 PL →

Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.

Used in enclosures (0)

No enclosure in the catalog uses this driver yet.