Sica 12 S 3 PL
Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 8 Ω |
| Fs | 42 Hz |
| Qts | 0.34 |
| Qes | 0.36 |
| Qms | 6.1 |
| Vas | 76.9 L |
| Sd | 530.9 cm² |
| Xmax | 7 mm |
| Re | 5.2 Ω |
| Bl | 16.8 T·m |
| Mms | 74.8 g |
| Pe | 400 W |
| Sensitivity | 95.8 dB |
Alignment hint
| EBP | 117 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 23.1 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| SICA 12 S 3 CP v2018 | 42 = | 0.34 = | 76.9 = | 6 -1 | 95.8 = | close | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| 18 Sound 12NTLX3500 | 39 -3 | 0.33 -0.01 | 79.6 +2.7 | 7.9 +0.9 | 95.5 -0.3 | close | + | |
| B&C 12 PS 32 | 44 +2 | 0.348 +0.01 | 82 +5.1 | 6 -1 | 95.8 = | close | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Eminence IMPERO 12 A | 42.8 +0.8 | 0.322 -0.02 | 70.2 -6.7 | 6.2 -0.8 | 95.8 = | close | Xmax 6.2 mm < 7 mm: lower excursion-limited SPL | + |
| Faital PRO 12FH500 | 48 +6 | 0.37 +0.03 | 77.4 +0.5 | 7.25 +0.25 | 96 +0.2 | close | 16 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 12NTLS3500 | 41 -1 | 0.34 = | 63 -13.9 | 7.9 +0.9 | 94.5 -1.3 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Beyma 12"G40 | 44 +2 | 0.3 -0.04 | 81 +4.1 | 7 = | 97 +1.2 | close | + | |
| LaVoce NBASS12-30-16 | 48 +6 | 0.34 = | 69.83 -7.07 | 7.3 +0.3 | 97.5 +1.7 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Beyma SM112/W | 42 = | 0.335 -0.01 | 90 +13.1 | 5.5 -1.5 | 96.1 +0.3 | close | 250 W vs 400 W: lower power handling · Xmax 5.5 mm < 7 mm: lower excursion-limited SPL | + |
| Faital PRO 12FH530 | 45 +3 | 0.39 +0.05 | 75.6 -1.3 | 7.5 +0.5 | 97 +1.2 | close | 16 Ω vs 8 Ω: amp load changes | + |
Compare the closest 3 against the 12 S 3 PL →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.