Selenium 10PW3
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 8 Ω |
| Fs | 73 Hz |
| Qts | 0.654 |
| Qes | 0.73 |
| Qms | 6.32 |
| Vas | 29 L |
| Sd | 350 cm² |
| Xmax | 1.3 mm |
| Re | 6.3 Ω |
| Bl | 10.6 T·m |
| Mms | 28.1 g |
| Pe | 150 W |
| Sensitivity | 94.9 dB |
Alignment hint
| EBP | 100 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 171.6 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Audax HT240T0 | 80 +7 | 0.657 = | 34.3 +5.3 | 1.5 +0.2 | 95.6 +0.7 | close | 80 W vs 150 W: lower power handling | + |
| Celestion K10-70 | 80 +7 | 0.672 +0.02 | 31 +2 | 2.2 +0.9 | 95.9 +1 | close | 70 W vs 150 W: lower power handling | + |
| Celestion BL 10-100 | 70 -3 | 0.608 -0.05 | 33 +4 | 3.3 +2 | 95.7 +0.8 | close | 100 W vs 150 W: lower power handling | + |
| LaVoce FBASS10-18-16 | 70 -3 | 0.57 -0.08 | 28.39 -0.61 | 4.8 +3.5 | 95 +0.1 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Tannoy DC200 | 66.5 -6.5 | 0.607 -0.05 | 25.8 -3.2 | 1.6 +0.3 | 92 -2.9 | usable | 40 W vs 150 W: lower power handling | + |
| Peerless FSL-1015R02-08 | 68.4 -4.6 | 0.616 -0.04 | 37.7 +8.7 | 2.2 +0.9 | 95.9 +1 | usable | 75 W vs 150 W: lower power handling | + |
| RCF L10CX1AK | 67.9 -5.1 | 0.59 -0.06 | 33 +4 | 3 +1.7 | 93.6 -1.3 | usable | 60 W vs 150 W: lower power handling | + |
| B&C 10 CLX 64 | 70 -3 | 0.627 -0.03 | 21 -8 | 2.3 +1 | 93.8 -1.1 | usable | 70 W vs 150 W: lower power handling | + |
| PD PD 102ER | 81.8 +8.8 | 0.523 -0.13 | 26 -3 | 1.3 = | 97.1 +2.2 | usable | 100 W vs 150 W: lower power handling | + |
| Precision Devices PD 102ER | 81.8 +8.8 | 0.523 -0.13 | 26 -3 | 1.3 = | 97.1 +2.2 | usable | 100 W vs 150 W: lower power handling | + |
Compare the closest 3 against the 10PW3 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.