Precision Devices PD 186
Thiele-Small parameters
| Nominal size | 18" |
|---|---|
| Impedance | 8 Ω |
| Fs | 27 Hz |
| Qts | 0.313 |
| Qes | 0.326 |
| Qms | 7.75 |
| Vas | 353 L |
| Sd | 1150 cm² |
| Xmax | 10.2 mm |
| Re | 5.5 Ω |
| Bl | 22.9 T·m |
| Mms | 182.5 g |
| Pe | 700 W |
| Sensitivity | 96.9 dB |
Alignment hint
| EBP | 83 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 86 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| PD PD 186 | 27 = | 0.313 = | 353 = | 10.2 = | 96.9 = | close | + | |
| RCF L 18P200N | 28 +1 | 0.306 -0.01 | 363 +10 | 9.8 -0.4 | 97 +0.1 | close | Xmax 9.8 mm < 10.2 mm: lower excursion-limited SPL | + |
| Precision Devices PD186 | 27 = | 0.312 = | 353 = | 8 -2.2 | 97 +0.1 | close | 16 Ω vs 8 Ω: amp load changes · Xmax 8 mm < 10.2 mm: lower excursion-limited SPL | + |
| RCF L 18P200N vp tlhp | 28 +1 | 0.306 -0.01 | 380 +27 | 9.8 -0.4 | 97.2 +0.3 | close | Xmax 9.8 mm < 10.2 mm: lower excursion-limited SPL | + |
| BMS 18N840V2 | 28.5 +1.5 | 0.314 = | 288 -65 | 10 -0.2 | 97.1 +0.2 | close | Xmax 10 mm < 10.2 mm: lower excursion-limited SPL | + |
| RCF LF18G400 | 28 +1 | 0.27 -0.04 | 360 +7 | 9 -1.2 | 97.5 +0.6 | close | Xmax 9 mm < 10.2 mm: lower excursion-limited SPL | + |
| RCF LF 18X400 v2 | 28 +1 | 0.278 -0.03 | 340 -13 | 9 -1.2 | 98 +1.1 | close | Xmax 9 mm < 10.2 mm: lower excursion-limited SPL | + |
| PD PD 18BR40 | 30 +3 | 0.32 +0.01 | 309 -44 | 9.3 -0.9 | 98 +1.1 | close | Xmax 9.3 mm < 10.2 mm: lower excursion-limited SPL | + |
| Precision Devices PD 18BR40 | 30 +3 | 0.32 +0.01 | 309 -44 | 9.3 -0.9 | 98 +1.1 | close | Xmax 9.3 mm < 10.2 mm: lower excursion-limited SPL | + |
| RCF LF18X400 | 28 +1 | 0.27 -0.04 | 340 -13 | 9 -1.2 | 97.5 +0.6 | close | Xmax 9 mm < 10.2 mm: lower excursion-limited SPL | + |
Compare the closest 3 against the PD 186 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.