Oxygen ALIUM 380
Thiele-Small parameters
| Nominal size | 15" |
|---|---|
| Impedance | 4 Ω |
| Fs | 18 Hz |
| Qts | 0.3 |
| Qes | 0.31 |
| Qms | 9.55 |
| Vas | 322 L |
| Sd | 908 cm² |
| Xmax | 7.9 mm |
| Re | 3.6 Ω |
| Bl | 19.2 T·m |
| Mms | 280.6 g |
| Pe | 200 W |
| Sensitivity | 93.3 dB |
Alignment hint
| EBP | 58 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 70.7 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Rythmik Audio DS1501 | 17.5 -0.5 | 0.315 +0.02 | 295 -27 | 7.5 -0.4 | 92.9 -0.4 | close | Xmax 7.5 mm < 7.9 mm: lower excursion-limited SPL | + |
| Dayton Audio ST385-8 | 18.8 +0.8 | 0.317 +0.02 | 301 -21 | 7.9 = | 91.2 -2.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Adire Audio TEMPEST DVC 4 Ohms config | 18.8 +0.8 | 0.377 +0.08 | 317 -5 | 8.2 +0.3 | 92.8 -0.5 | close | + | |
| TC Sounds TC2000 vp | 18 = | 0.323 +0.02 | 267 -55 | 14 +6.1 | 92.5 -0.8 | close | + | |
| SB Acoustics SB42FHCL75-6 | 18.4 +0.4 | 0.307 +0.01 | 462 +140 | 11.5 +3.6 | 93.9 +0.6 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Audiotechnology FLEXUNIT 15 F 102 25 10 KAP | 22 +4 | 0.29 -0.01 | 410 +88 | 8.6 +0.7 | 93.5 +0.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio DCS385-4 | 17.5 -0.5 | 0.389 +0.09 | 311 -11 | 9.3 +1.4 | 91.8 -1.5 | usable | + | |
| Monacor SPH-380TC série | 21.5 +3.5 | 0.279 -0.02 | 275 -47 | 7.4 -0.5 | 91.9 -1.4 | usable | 8 Ω vs 4 Ω: amp load changes · Xmax 7.4 mm < 7.9 mm: lower excursion-limited SPL | + |
| Orion Audio 2NT 15 | 18 = | 0.248 -0.05 | 419.1 +97.1 | 10.5 +2.6 | 92.5 -0.8 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Visaton TIW400 | 23 +5 | 0.348 +0.05 | 300 -22 | 10.6 +2.7 | 93.3 = | usable | 8 Ω vs 4 Ω: amp load changes | + |
Compare the closest 3 against the ALIUM 380 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.