Monacor SP-300GI
Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 8 Ω |
| Fs | 65 Hz |
| Qts | 0.969 |
| Qes | 1.28 |
| Qms | 3.99 |
| Vas | 75 L |
| Sd | 510 cm² |
| Xmax | 3.2 mm |
| Re | 6.5 Ω |
| Bl | 7.8 T·m |
| Mms | 29.1 g |
| Pe | 150 W |
| Sensitivity | 94.9 dB |
Alignment hint
| EBP | 51 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Mercuriale PTR 306 M0 | 58 -7 | 0.808 -0.16 | 70.1 -4.9 | 3.9 +0.7 | 94.6 -0.3 | usable | + | |
| Celestion TF 1215 | 62 -3 | 0.857 -0.11 | 69 -6 | 2.5 -0.7 | 96.2 +1.3 | usable | Xmax 2.5 mm < 3.2 mm: lower excursion-limited SPL | + |
| Fonestar FPW 350 | 52 -13 | 0.876 -0.09 | 65 -10 | 3.7 +0.5 | 91.8 -3.1 | usable | + | |
| SICA 12 D 1.5 CS 8 Ohms | 62 -3 | 0.748 -0.22 | 63.5 -11.5 | 2.7 -0.5 | 96.8 +1.9 | usable | 100 W vs 150 W: lower power handling · Xmax 2.7 mm < 3.2 mm: lower excursion-limited SPL | + |
| Sica 12 D 1.5 CS | 62 -3 | 0.75 -0.22 | 63.5 -11.5 | 2.7 -0.5 | 96.9 +2 | usable | Xmax 2.7 mm < 3.2 mm: lower excursion-limited SPL | + |
| Celestion F12M-150 Triple Cone | 69.4 +4.4 | 0.906 -0.06 | 46.9 -28.1 | 2.3 -0.9 | 95.2 +0.3 | usable | Xmax 2.3 mm < 3.2 mm: lower excursion-limited SPL | + |
| Elokance 12WF500 | 50 -15 | 1.102 +0.13 | 99.1 +24.1 | 3.6 +0.4 | 93.2 -1.7 | usable | + | |
| Siemens KL405 | 75.8 +10.8 | 0.77 -0.2 | 68 -7 | 3 -0.2 | 99.2 +4.3 | usable | Xmax 3 mm < 3.2 mm: lower excursion-limited SPL | + |
| Siare 31TE vp | 53.4 -11.6 | 0.746 -0.22 | 62 -13 | 4.1 +0.9 | 93.8 -1.1 | usable | + | |
| Supravox T285HF64 | 55 -10 | 0.6 -0.37 | 74.6 -0.4 | 3.3 +0.1 | 95.6 +0.7 | usable | 70 W vs 150 W: lower power handling | + |
Compare the closest 3 against the SP-300GI →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.