Kenwood XR-W1204
Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 4 Ω |
| Fs | 21.5 Hz |
| Qts | 0.341 |
| Qes | 0.356 |
| Qms | 8.143 |
| Vas | 125.386 L |
| Sd | 601 cm² |
| Xmax | 10.8 mm |
| Re | 3.65 Ω |
| Bl | 17.6 T·m |
| Mms | 223.8 g |
| Pe | 400 W |
| Sensitivity | 87.3 dB |
Alignment hint
| EBP | 60 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 38 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Visaton TIW 360X | 21 -0.5 | 0.34 = | 140 +14.61 | 12.5 +1.7 | 87.3 = | close | 8 Ω vs 4 Ω: amp load changes · 300 W vs 400 W: lower power handling | + |
| Helix W-12 COMPETITION | 21.4 -0.1 | 0.3 -0.04 | 118.6 -6.79 | 11 +0.2 | 87.3 = | close | + | |
| Visaton TIW360X | 21 -0.5 | 0.336 -0.01 | 140 +14.61 | 12.2 +1.4 | 88.8 +1.5 | close | 8 Ω vs 4 Ω: amp load changes · 300 W vs 400 W: lower power handling | + |
| Eminence LAB 12C | 23 +1.5 | 0.33 -0.01 | 128.31 +2.92 | 13 +2.2 | 88.9 +1.6 | close | + | |
| Eminence LAB 12 | | 22 +0.5 | 0.38 +0.04 | 125.2 -0.19 | 13 +2.2 | 89.2 +1.9 | close | 6 Ω vs 4 Ω: amp load changes | + |
| Eminence LAB 12 | 22 +0.5 | 0.379 +0.04 | 125.2 -0.19 | 11 +0.2 | 90 +2.7 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Eminence LAB 12 C | 22.9 +1.4 | 0.33 -0.01 | 128.3 +2.91 | 11 +0.2 | 92.6 +5.3 | close | + | |
| Pioneer TSW 304 C | 21 -0.5 | 0.342 = | 146 +20.61 | 11 +0.2 | 92 +4.7 | close | 300 W vs 400 W: lower power handling | + |
| Image Dynamics IDMAX 12D4V3 | 20 -1.5 | 0.336 -0.01 | 165 +39.61 | 12.3 +1.5 | 88.4 +1.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| GR Research SW-12-08 | 23.1 +1.6 | 0.339 = | 115.7 -9.69 | 8 -2.8 | 89.1 +1.8 | close | 8 Ω vs 4 Ω: amp load changes · 200 W vs 400 W: lower power handling · Xmax 8 mm < 10.8 mm: lower excursion-limited SPL | + |
Compare the closest 3 against the XR-W1204 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.