JL Audio 10TW3-D4
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 16 Ω |
| Fs | 32.3 Hz |
| Qts | 0.62 |
| Qes | 0.656 |
| Qms | 11.35 |
| Vas | 19.8 L |
| Sd | 365 cm² |
| Xmax | 7 mm |
| Re | 9.04 Ω |
| Bl | 25.3 T·m |
| Mms | 228.8 g |
| Pe | 400 W |
| Sensitivity | 81.5 dB |
Alignment hint
| EBP | 49 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 65.8 L |
EBP < 50: favours a sealed (closed) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Alpine SWR-10D4 | 32 -0.3 | 0.544 -0.08 | 18 -1.8 | 10 +3 | 82.2 +0.7 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Alpine SWX-1043D Type-X | 31 -1.3 | 0.54 -0.08 | 18 -1.8 | 10.3 +3.3 | 82.1 +0.6 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Rockford Fosgate T0D410 | 31 -1.3 | 0.541 -0.08 | 17 -2.8 | 8.3 +1.3 | 82.4 +0.9 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Rockford Fosgate T1D410 | 36 +3.7 | 0.647 +0.03 | 15.7 -4.1 | 7.3 +0.3 | 82.9 +1.4 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| HiVi SP10 | 34 +1.7 | 0.573 -0.05 | 17.1 -2.7 | 6.7 -0.3 | 85.8 +4.3 | usable | 4 Ω vs 16 Ω: amp load changes · Xmax 6.7 mm < 7 mm: lower excursion-limited SPL | + |
| Kenwood KFC-XW100F | 38.6 +6.3 | 0.72 +0.1 | 21.05 +1.25 | 7.5 +0.5 | 83.4 +1.9 | usable | 4 Ω vs 16 Ω: amp load changes · 250 W vs 400 W: lower power handling | + |
| Audiomobile GTS 2110 S4 | 28 -4.3 | 0.59 -0.03 | 25.5 +5.7 | 12.2 +5.2 | 81 -0.5 | usable | 4 Ω vs 16 Ω: amp load changes | + |
| Kenwood KFC-WPS1000F | 38.6 +6.3 | 0.722 +0.1 | 21.05 +1.25 | 8 +1 | 83.4 +1.9 | usable | 4 Ω vs 16 Ω: amp load changes · 250 W vs 400 W: lower power handling | + |
| hertz Hertz Audio ML2500.3 | 33 +0.7 | 0.598 -0.02 | 23.5 +3.7 | 10.3 +3.3 | 87.8 +6.3 | usable | 4 Ω vs 16 Ω: amp load changes | + |
| Alpine SWR-10D2 | 31 -1.3 | 0.505 -0.11 | 18 -1.8 | 10 +3 | 85.1 +3.6 | usable | 4 Ω vs 16 Ω: amp load changes | + |
Compare the closest 3 against the 10TW3-D4 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.