Faital PRO 6RS140

6" · 16 Ω · 200 W · 92 dB · datasheet ↗

Thiele-Small parameters

Nominal size6"
Impedance16 Ω
Fs65 Hz
Qts0.36
Qes0.38
Qms6
Vas9.9 L
Sd133 cm²
Xmax5.5 mm
Re12.6 Ω
Mms15 g
Pe200 W
Sensitivity92 dB

Alignment hint

EBP171 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 3.5 L

EBP > 100: favours a ported (bass-reflex) alignment.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Substitute candidates

DriverFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)FitNotesCompare
LaVoce WAN061.80-1662 -30.31 -0.0510.26 +0.365.2 -0.392.5 +0.5closeXmax 5.2 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 NR 2 PL60.5 -4.50.33 -0.039.4 -0.54 -1.591.4 -0.6usable8 Ω vs 16 Ω: amp load changes · Xmax 4 mm < 5.5 mm: lower excursion-limited SPL+
Faital PRO 6RS14065 =0.27 -0.099.3 -0.65.6 +0.193 +1usable8 Ω vs 16 Ω: amp load changes+
Sica 6 N 2 PL68 +30.33 -0.038.7 -1.23.5 -292.3 +0.3usable8 Ω vs 16 Ω: amp load changes · Xmax 3.5 mm < 5.5 mm: lower excursion-limited SPL+
LaVoce WAF061.8065 =0.42 +0.067.26 -2.644.9 -0.691 -1usable8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4.9 mm < 5.5 mm: lower excursion-limited SPL+
BMS 6S11780 +150.43 +0.0710.4 +0.55 -0.593 +1usable130 W vs 200 W: lower power handling · Xmax 5 mm < 5.5 mm: lower excursion-limited SPL+
LaVoce WAN061.8060 -50.27 -0.0911.18 +1.285.2 -0.393 +1usable8 Ω vs 16 Ω: amp load changes · Xmax 5.2 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 E 1.5 CS60 -50.38 +0.0211.3 +1.42.5 -391.5 -0.5usable8 Ω vs 16 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 2.5 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 L 1.5 SL59 -60.39 +0.0311 +1.12.5 -391 -1usable8 Ω vs 16 Ω: amp load changes · 130 W vs 200 W: lower power handling · Xmax 2.5 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 H 1.5 CP46 -190.35 -0.0116.6 +6.76 +0.589.4 -2.6usable8 Ω vs 16 Ω: amp load changes · 120 W vs 200 W: lower power handling+

Compare the closest 3 against the 6RS140 →

Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.

Used in enclosures (0)