← all drivers

Faital PRO 6FE400

6" · 16 Ω · 200 W · 94 dB · datasheet ↗

Thiele-Small parameters

Nominal size6"
Impedance16 Ω
Fs100 Hz
Qts0.5
Qes0.57
Qms3.7
Vas5.5 L
Sd141 cm²
Xmax4.77 mm
Re12 Ω
Mms12.9 g
Pe200 W
Sensitivity94 dB

Alignment hint

EBP175 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 5.5 L

EBP > 100: favours a ported (bass-reflex) alignment.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Substitute candidates

DriverFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)FitNotesCompare
Faital PRO 6FE300100 =0.46 -0.044.7 -0.83.9 -0.8794 =close8 Ω vs 16 Ω: amp load changes · Xmax 3.9 mm < 4.77 mm: lower excursion-limited SPL+
Eminence ALPHA-6A103 +30.54 +0.045.8 +0.33.5 -1.2793.6 -0.4close8 Ω vs 16 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 3.5 mm < 4.77 mm: lower excursion-limited SPL+
Eminence ALPHA 6C107 +70.45 -0.055.7 +0.23.5 -1.2793.3 -0.7usable4 Ω vs 16 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 3.5 mm < 4.77 mm: lower excursion-limited SPL+
Faital PRO 6FE400100 =0.36 -0.145 -0.54.77 =94 =usable8 Ω vs 16 Ω: amp load changes+
Faital PRO 6PR110100 =0.53 +0.035.6 +0.12.75 -2.0296 +2usable8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 2.75 mm < 4.77 mm: lower excursion-limited SPL+
LaVoce WSN061.52-16108 +80.53 +0.034.46 -1.043.7 -1.0793 -1usable125 W vs 200 W: lower power handling · Xmax 3.7 mm < 4.77 mm: lower excursion-limited SPL+
BMS 6N16089 -110.47 -0.037.7 +2.25 +0.2393 -1usable130 W vs 200 W: lower power handling+
Faital PRO 6FE400100 =0.36 -0.144.9 -0.64.87 +0.193 -1usable4 Ω vs 16 Ω: amp load changes+
LaVoce WSN061.5290 -100.39 -0.115.92 +0.423.8 -0.9794 =usable8 Ω vs 16 Ω: amp load changes · 125 W vs 200 W: lower power handling · Xmax 3.8 mm < 4.77 mm: lower excursion-limited SPL+
LaVoce WSF061.52-1693 -70.42 -0.086.92 +1.423.7 -1.0793.5 -0.5usable125 W vs 200 W: lower power handling · Xmax 3.7 mm < 4.77 mm: lower excursion-limited SPL+

Compare the closest 3 against the 6FE400 →

Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.

Used in enclosures (0)

No enclosure in the catalog uses this driver yet.