Faital PRO 15FH520-4 v2021
Thiele-Small parameters
| Nominal size | 15" |
|---|---|
| Impedance | 4 Ω |
| Fs | 38 Hz |
| Qts | 0.337 |
| Qes | 0.35 |
| Qms | 9 |
| Vas | 146.2 L |
| Sd | 813 cm² |
| Xmax | 7.4 mm |
| Re | 2.7 Ω |
| Bl | 14.3 T·m |
| Mms | 111.2 g |
| Pe | 600 W |
| Sensitivity | 100.3 dB |
Alignment hint
| EBP | 109 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 43 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 15FH520-4 | 38 = | 0.337 = | 156.6 +10.4 | 7.8 +0.4 | 100.6 +0.3 | close | + | |
| Oberton 15MB500 | 41.5 +3.5 | 0.339 = | 161.54 +15.34 | 7.75 +0.35 | 100 -0.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| PD PD 15BR40 | 38.7 +0.7 | 0.34 = | 158.3 +12.1 | 7.9 +0.5 | 98.1 -2.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Precision Devices PD 15BR40 | 38.7 +0.7 | 0.34 = | 158.3 +12.1 | 7.9 +0.5 | 98.1 -2.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Faital PRO 15FH500 vp2 | 40 +2 | 0.335 = | 146.9 +0.7 | 6.7 -0.7 | 98.3 -2 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6.7 mm < 7.4 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH500 vp1 | 40 +2 | 0.328 -0.01 | 146.1 -0.1 | 6.7 -0.7 | 98.4 -1.9 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6.7 mm < 7.4 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH520 | 38 = | 0.34 = | 153.2 +7 | 9.15 +1.75 | 97 -3.3 | close | + | |
| BMS 15S330 | 39 +1 | 0.32 -0.02 | 152 +5.8 | 8 +0.6 | 98 -2.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| RCF L 15P200AK-II | 38 = | 0.336 = | 139 -7.2 | 8.3 +0.9 | 96.3 -4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Beyma 15MCB700 | 44 +6 | 0.34 = | 148 +1.8 | 7 -0.4 | 99 -1.3 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 7 mm < 7.4 mm: lower excursion-limited SPL | + |
Compare the closest 3 against the 15FH520-4 v2021 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.