Conrad DS-100i
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 4 Ω |
| Fs | 22.5 Hz |
| Qts | 0.188 |
| Qes | 0.2 |
| Qms | 3.13 |
| Vas | 112.2 L |
| Sd | 346 cm² |
| Xmax | 1.5 mm |
| Re | 3.56 Ω |
| Bl | 13.7 T·m |
| Mms | 74.9 g |
| Pe | 100 W |
| Sensitivity | 93.6 dB |
Alignment hint
| EBP | 113 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 8.5 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| JBL LE111A | 25 +2.5 | 0.175 -0.01 | 101.9 -10.3 | 4.8 +3.3 | 92.9 -0.7 | usable | 8 Ω vs 4 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
| JBL 2121 | 35 +12.5 | 0.193 +0.01 | 110.4 -1.8 | 1.5 = | 96.4 +2.8 | usable | 8 Ω vs 4 Ω: amp load changes · 50 W vs 100 W: lower power handling | + |
| Focal 10C 012-DB | 26.3 +3.8 | 0.238 +0.05 | 134.7 +22.5 | 2.5 +1 | 93.8 +0.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| ATC SB75-234 LC | 26 +3.5 | 0.224 +0.04 | 120 +7.8 | 5 +3.5 | 91.8 -1.8 | usable | 8 Ω vs 4 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
| Audax PR240Z2 | 25 +2.5 | 0.261 +0.07 | 112 -0.2 | 5 +3.5 | 94.1 +0.5 | usable | + | |
| Focal 10C 012DB | 26.3 +3.8 | 0.247 +0.06 | 135 +22.8 | 2.5 +1 | 93.6 = | usable | 8 Ω vs 4 Ω: amp load changes | + |
| ATC PA75-234 BLCR | 27 +4.5 | 0.181 -0.01 | 79 -33.2 | 4 +2.5 | 92.3 -1.3 | usable | 8 Ω vs 4 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
| Fostex FW 250 | 23 +0.5 | 0.225 +0.04 | 150 +37.8 | 4.5 +3 | 91.8 -1.8 | usable | 8 Ω vs 4 Ω: amp load changes · 50 W vs 100 W: lower power handling | + |
| Audiotechnology 10C772510KAP | 25 +2.5 | 0.24 +0.05 | 110 -2.2 | 8.6 +7.1 | 92.1 -1.5 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Klipsch K1089-AV | 31 +8.5 | 0.216 +0.03 | 106.2 -6 | 4.4 +2.9 | 94.8 +1.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
Compare the closest 3 against the DS-100i →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.