Ciare CW322
Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 4 Ω |
| Fs | 22 Hz |
| Qts | 0.251 |
| Qes | 0.27 |
| Qms | 3.52 |
| Vas | 355 L |
| Sd | 517 cm² |
| Xmax | 5 mm |
| Re | 3.2 Ω |
| Bl | 9.5 T·m |
| Mms | 55.2 g |
| Pe | 100 W |
| Sensitivity | 97.4 dB |
Alignment hint
| EBP | 81 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 51.2 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Siare 31TE V2 | 23 +1 | 0.265 +0.01 | 387 +32 | 5 = | 95.9 -1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| AER STUDIO BASS | 21 -1 | 0.237 -0.01 | 360 +5 | 5.2 +0.2 | 94.3 -3.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Visaton W300S4 | 23 +1 | 0.253 = | 300 -55 | 7 +2 | 96.4 -1 | close | + | |
| Siare 31TE | 23 +1 | 0.265 +0.01 | 322 -33 | 5 = | 95.1 -2.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Monacor SPH-315 | 22 = | 0.235 -0.02 | 330 -25 | 4.5 -0.5 | 94.5 -2.9 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 4.5 mm < 5 mm: lower excursion-limited SPL | + |
| Monacor SPP-300/AD | 23 +1 | 0.265 +0.01 | 305 -50 | 5 = | 93.9 -3.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Vifa M30W0-49-08 | 21 -1 | 0.225 -0.03 | 400 +45 | 6 +1 | 95.2 -2.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Monacor SPH-300TC | 23 +1 | 0.239 -0.01 | 290 -65 | 4 -1 | 97.3 -0.1 | close | Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
| Monacor SPH-300TC v2 | 23 +1 | 0.239 -0.01 | 290 -65 | 4 -1 | 97.3 -0.1 | close | Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
| SEAS 33F-WKA | 22 = | 0.209 -0.04 | 310 -45 | 5 = | 95 -2.4 | usable | 8 Ω vs 4 Ω: amp load changes · 70 W vs 100 W: lower power handling | + |
Compare the closest 3 against the CW322 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.