Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 8 Ω |
| Fs | 28.6 Hz |
| Qts | 0.24 |
| Qes | 0.25 |
| Qms | 5.9 |
| Vas | 85.5 L |
| Sd | 498 cm² |
| Xmax | 8 mm |
| Re | 6 Ω |
| Bl | 23 T·m |
| Mms | 127 g |
| Pe | 600 W |
| Sensitivity | 96 dB |
Alignment hint
| EBP | 114 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 11.1 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| BMS 12S330 v2016 | 28.6 = | 0.24 = | 85.5 = | 8 = | 92.3 -3.7 | close | + | |
| BMS 12N630 | 28.6 = | 0.33 +0.09 | 85.5 = | 8 = | 96 = | close | + | |
| Fane FC-123F01 | 34 +5.4 | 0.235 -0.01 | 110 +24.5 | 7.8 -0.2 | 96.1 +0.1 | usable | Xmax 7.8 mm < 8 mm: lower excursion-limited SPL | + |
| DLS SP12 | 30.5 +1.9 | 0.237 = | 98.8 +13.3 | 9.1 +1.1 | 100.5 +4.5 | usable | 2 Ω vs 8 Ω: amp load changes | + |
| Raveland BSW 124-II | 28 -0.6 | 0.252 +0.01 | 91.4 +5.9 | 5.4 -2.6 | 94.7 -1.3 | usable | 4 Ω vs 8 Ω: amp load changes · 200 W vs 600 W: lower power handling · Xmax 5.4 mm < 8 mm: lower excursion-limited SPL | + |
| RCF L 12P300 | 40 +11.4 | 0.242 = | 81 -4.5 | 7.8 -0.2 | 96.7 +0.7 | usable | Xmax 7.8 mm < 8 mm: lower excursion-limited SPL | + |
| BMS 12S305 | 35 +6.4 | 0.265 +0.03 | 82 -3.5 | 11 +3 | 95 -1 | usable | + | |
| SICA 12SR3PL | 27.4 -1.2 | 0.27 +0.03 | 103.1 +17.6 | 7 -1 | 94.8 -1.2 | usable | 4 Ω vs 8 Ω: amp load changes · 400 W vs 600 W: lower power handling · Xmax 7 mm < 8 mm: lower excursion-limited SPL | + |
| Beyma POWER 12 COMPETITION | 29 +0.4 | 0.27 +0.03 | 122 +36.5 | 9 +1 | 95.1 -0.9 | usable | + | |
| BMS 12S330 v2018 | 28.6 = | 0.295 +0.05 | 81.4 -4.1 | 8 = | 91.1 -4.9 | usable | + |
Compare the closest 3 against the 12S330 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.