B&C 15NW100
Thiele-Small parameters
| Nominal size | 15" |
|---|---|
| Impedance | 4 Ω |
| Fs | 34 Hz |
| Qts | 0.23 |
| Qes | 0.23 |
| Qms | 5.41 |
| Vas | 126.1 L |
| Sd | 855 cm² |
| Xmax | 9 mm |
| Re | 3.7 Ω |
| Bl | 24.54 T·m |
| Mms | 180 g |
| Pe | 1000 W |
| Sensitivity | 95 dB |
Alignment hint
| EBP | 148 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 14.9 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| B&C 15NW100 | 33 -1 | 0.22 -0.01 | 139 +12.9 | 9 = | 97 +2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 15 SW 115 | 35 +1 | 0.237 +0.01 | 110 -16.1 | 8.8 -0.2 | 96.6 +1.6 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 8.8 mm < 9 mm: lower excursion-limited SPL | + |
| B&C 15SW115 | 35 +1 | 0.24 +0.01 | 110 -16.1 | 13.5 +4.5 | 96 +1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 15TBX100 | 34 = | 0.27 +0.04 | 129.6 +3.5 | 9 = | 93 -2 | close | + | |
| B&C 15SW115 | 34 = | 0.22 -0.01 | 105 -21.1 | 13.5 +4.5 | 96 +1 | close | + | |
| RCF LF15N401 | 34 = | 0.22 -0.01 | 160 +33.9 | 9 = | 97 +2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 15NLW4500 | 35 +1 | 0.2 -0.03 | 126 -0.1 | 14.5 +5.5 | 96.6 +1.6 | close | + | |
| Oberton 15PD601 | 38.2 +4.2 | 0.228 = | 133.31 +7.21 | 8.5 -0.5 | 98 +3 | close | 8 Ω vs 4 Ω: amp load changes · 600 W vs 1000 W: lower power handling · Xmax 8.5 mm < 9 mm: lower excursion-limited SPL | + |
| BMS 15N840V2-8 | 35.6 +1.6 | 0.268 +0.04 | 130 +3.9 | 8.7 -0.3 | 97.2 +2.2 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 8.7 mm < 9 mm: lower excursion-limited SPL | + |
| B&C 15 NW 100 | 33 -1 | 0.218 -0.01 | 139 +12.9 | 7.4 -1.6 | 97.3 +2.3 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 7.4 mm < 9 mm: lower excursion-limited SPL | + |
Compare the closest 3 against the 15NW100 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.