B&C 12FW76
Thiele-Small parameters
| Nominal size | 12" |
|---|---|
| Impedance | 8 Ω |
| Fs | 54 Hz |
| Qts | 0.18 |
| Qes | 0.18 |
| Qms | 3.8 |
| Vas | 45 L |
| Sd | 522 cm² |
| Xmax | 7 mm |
| Re | 5.1 Ω |
| Bl | 26.4 T·m |
| Mms | 75 g |
| Pe | 500 W |
| Sensitivity | 100 dB |
Alignment hint
| EBP | 300 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 3.1 L |
EBP > 100: favours a ported (bass-reflex) alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| B&C 12FW76 | 54 = | 0.18 = | 48.5 +3.5 | 7 = | 99 -1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| RCF CX12N351 | 58 +4 | 0.2 +0.02 | 47 +2 | 6 -1 | 98.2 -1.8 | close | 90 W vs 500 W: lower power handling · Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| RCF MB 12N405 | 52 -2 | 0.203 +0.02 | 53 +8 | 5.7 -1.3 | 99.5 -0.5 | usable | Xmax 5.7 mm < 7 mm: lower excursion-limited SPL | + |
| B&C 12 FW 76 | 54 = | 0.172 -0.01 | 45 = | 3.3 -3.7 | 99.9 -0.1 | usable | Xmax 3.3 mm < 7 mm: lower excursion-limited SPL | + |
| 18 Sound 12ND940 | 49 -5 | 0.2 +0.02 | 64.8 +19.8 | 7.6 +0.6 | 100 = | usable | + | |
| Precision Devices PD121 | 59 +5 | 0.201 +0.02 | 54 +9 | 5 -2 | 100 = | usable | 16 Ω vs 8 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 5 mm < 7 mm: lower excursion-limited SPL | + |
| B&C 12NDL76 | 50 -4 | 0.19 +0.01 | 70 +25 | 6 -1 | 100 = | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| B&C 12NDL76 | 50 -4 | 0.2 +0.02 | 73 +28 | 7 = | 100 = | usable | + | |
| Sica 12 F 4 CP | 46 -8 | 0.2 +0.02 | 52 +7 | 6 -1 | 97.8 -2.2 | usable | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| B&C 12MH32 | 53 -1 | 0.19 +0.01 | 63 +18 | 5 -2 | 101 +1 | usable | Xmax 5 mm < 7 mm: lower excursion-limited SPL | + |
Compare the closest 3 against the 12FW76 →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.