ATS Acoustics HG25 vp Double ferrite
Thiele-Small parameters
| Nominal size | 10" |
|---|---|
| Impedance | 8 Ω |
| Fs | 29.8 Hz |
| Qts | 0.26 |
| Qes | 0.298 |
| Qms | 2.07 |
| Vas | 94.2 L |
| Sd | 346 cm² |
| Xmax | 4 mm |
| Re | 5.8 Ω |
| Bl | 13.6 T·m |
| Mms | 50.8 g |
| Pe | 150 W |
| Sensitivity | 92.6 dB |
Alignment hint
| EBP | 100 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 14.7 L |
EBP 50-100: works in either a sealed or ported alignment.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Substitute candidates
| Driver | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Fit | Notes | Compare |
|---|---|---|---|---|---|---|---|---|
| Monacor SPH-275C | 31 +1.2 | 0.287 +0.03 | 100 +5.8 | 6 +2 | 93.1 +0.5 | close | + | |
| SEAS 25F-EWX 4 vp | 27 -2.8 | 0.289 +0.03 | 100 +5.8 | 4 = | 93.2 +0.6 | close | 4 Ω vs 8 Ω: amp load changes · 60 W vs 150 W: lower power handling | + |
| Monacor SPH-250TC v2009 | 26 -3.8 | 0.25 -0.01 | 84 -10.2 | 4.5 +0.5 | 93.1 +0.5 | close | 4 Ω vs 8 Ω: amp load changes · 100 W vs 150 W: lower power handling | + |
| Monacor SPH-250TC v2011 | 26 -3.8 | 0.25 -0.01 | 84 -10.2 | 4.5 +0.5 | 93.1 +0.5 | close | 4 Ω vs 8 Ω: amp load changes · 100 W vs 150 W: lower power handling | + |
| HiVi S10IIP | 27 -2.8 | 0.287 +0.03 | 98.1 +3.9 | 7 +3 | 92.9 +0.3 | close | + | |
| Volt B250.8 v2014 | 32 +2.2 | 0.302 +0.04 | 89 -5.2 | 5.5 +1.5 | 92.4 -0.2 | close | + | |
| Alpine 6013 | 30 +0.2 | 0.313 +0.05 | 96 +1.8 | 3.8 -0.2 | 94.8 +2.2 | close | 4 Ω vs 8 Ω: amp load changes · 100 W vs 150 W: lower power handling · Xmax 3.8 mm < 4 mm: lower excursion-limited SPL | + |
| SEAS 25F-EWX-4 | 27.5 -2.3 | 0.277 +0.02 | 92 -2.2 | 2.9 -1.1 | 93.1 +0.5 | close | 25 W vs 150 W: lower power handling · Xmax 2.9 mm < 4 mm: lower excursion-limited SPL | + |
| Audax PR240Z2 | 25 -4.8 | 0.261 = | 112 +17.8 | 5 +1 | 94.1 +1.5 | usable | 4 Ω vs 8 Ω: amp load changes · 100 W vs 150 W: lower power handling | + |
| Vifa M26WR09-04 | 27 -2.8 | 0.28 +0.02 | 113 +18.8 | 6.5 +2.5 | 93 +0.4 | usable | + |
Compare the closest 3 against the HG25 vp Double ferrite →
Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.
Used in enclosures (0)
No enclosure in the catalog uses this driver yet.