← all drivers

AE Speakers SBP15-4

15" · 4 Ω · 500 W · 95.4 dB · datasheet ↗

Thiele-Small parameters

Nominal size15"
Impedance4 Ω
Fs21.3 Hz
Qts0.432
Qes0.47
Qms5.35
Vas364 L
Sd855 cm²
Xmax14 mm
Re2.7 Ω
Bl11 T·m
Mms157.2 g
Pe500 W
Sensitivity95.4 dB

Alignment hint

EBP45 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 216.8 L

EBP < 50: favours a sealed (closed) alignment.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Substitute candidates

DriverFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)FitNotesCompare
AE Speakers SBP15-821.3 =0.432 =364 =14 =92.3 -3.1close8 Ω vs 4 Ω: amp load changes+
Dayton Audio RSS390HF-418 -3.30.423 -0.01281.8 -82.214 =91.1 -4.3usable+
SB Acoustics SB42FHC75-622.5 +1.20.372 -0.06318 -4610.1 -3.994 -1.4usable8 Ω vs 4 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 10.1 mm < 14 mm: lower excursion-limited SPL+
Dayton Audio DVC385-8820.9 -0.40.446 +0.01237 -12711.1 -2.993.8 -1.6usable350 W vs 500 W: lower power handling · Xmax 11.1 mm < 14 mm: lower excursion-limited SPL+
Dayton Audio DCS380-4 v201721.5 +0.20.434 =267 -978.4 -5.693.7 -1.7usable250 W vs 500 W: lower power handling · Xmax 8.4 mm < 14 mm: lower excursion-limited SPL+
Oxygen AIR 15.125 +3.70.465 +0.03262.1 -101.911.1 -2.994.5 -0.9usableXmax 11.1 mm < 14 mm: lower excursion-limited SPL+
Fostex FW 405 N27 +5.70.446 +0.01392.5 +28.57.6 -6.494.7 -0.7usable8 Ω vs 4 Ω: amp load changes · 150 W vs 500 W: lower power handling · Xmax 7.6 mm < 14 mm: lower excursion-limited SPL+
Visaton TIW 400-823 +1.70.35 -0.08300 -6427 +1391.8 -3.6usable8 Ω vs 4 Ω: amp load changes · 300 W vs 500 W: lower power handling+
Visaton TIW40023 +1.70.348 -0.08300 -6410.6 -3.493.3 -2.1usable8 Ω vs 4 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 10.6 mm < 14 mm: lower excursion-limited SPL+
JBL 2216ND (pour JBL 4367)28.3 +70.376 -0.06333 -319.5 -4.596.3 +0.9usable8 Ω vs 4 Ω: amp load changes · Xmax 9.5 mm < 14 mm: lower excursion-limited SPL+

Compare the closest 3 against the SBP15-4 →

Ranked on parameter similarity only (Qts, Fs, Vas, Xmax, sensitivity). Same nominal size required. A hint, not a simulation, model the swap before cutting or buying.

Used in enclosures (0)

No enclosure in the catalog uses this driver yet.